SPLIT-SLAB DUAL SEISMIC FOAM SEAL SYSTEM (SSD)
SSD-C | Total Movement | Joint Opening "A" | Slide Plate "B" | Slide Plate Thickness "C" | ||||||||||||
Seismic Min. | Thermal Min. | Nominal | Thermal Max. | Seismic Max. | ||||||||||||
SSD-C-400 | 4.67 | 119 | 1.33 | 34 | 2.00 | 51 | 4.00 | 102 | 6.00 | 152 | 6.00 | 152 | 6.875 | 175 | 0.375 | 10 |
SSD-C-500 | 5.83 | 148 | 1.67 | 42 | 2.50 | 64 | 5.00 | 127 | 7.50 | 191 | 7.50 | 191 | 7.875 | 200 | 0.375 | 10 |
SSD-C-600 | 7.00 | 178 | 2.00 | 51 | 3.00 | 76 | 6.00 | 152 | 9.00 | 229 | 9.00 | 229 | 8.875 | 225 | 0.375 | 10 |
SSD-C-700 | 8.17 | 208 | 2.33 | 59 | 3.50 | 89 | 7.00 | 178 | 10.50 | 267 | 10.50 | 267 | 9.875 | 251 | 0.375 | 10 |
SSD-C-800 | 9.33 | 237 | 2.67 | 68 | 4.00 | 102 | 8.00 | 203 | 12.00 | 305 | 12.00 | 305 | 10.875 | 276 | 0.375 | 10 |
SSD-C-900 | 10.50 | 267 | 3.00 | 76 | 4.50 | 114 | 9.00 | 229 | 13.50 | 343 | 13.50 | 343 | 11.875 | 302 | 0.375 | 10 |
SSD-C-1000 | 11.67 | 296 | 3.33 | 85 | 5.00 | 127 | 10.00 | 254 | 15.00 | 381 | 15.00 | 381 | 12.875 | 327 | 0.375 | 10 |
SSD-C-1100 | 12.83 | 326 | 3.67 | 93 | 5.50 | 140 | 11.00 | 279 | 15.00 | 381 | 16.50 | 419 | 13.875 | 352 | 0.500 | 13 |
SSD-C-1200 | 14.00 | 356 | 4.00 | 102 | 6.00 | 152 | 12.00 | 305 | 16.00 | 406 | 18.00 | 457 | 14.875 | 378 | 0.500 | 13 |
Dimensions are shown in inches (bold) and millimeters. Thermal Maximum determined on a project specific basis.
Slide plate thickness is based on the maximum thermal opening for regular vehicle loading.
Contact MM for other sizes and project-specific designs.