GALVANIZED IMPACT DAMPING SYSTEM (GID)


GID Main Page | Switch to GID-C

Fire Rated System icon represents approvals and listings with accredited laboratories. Heavy Duty System icon represents heavy-duty load carrying capability for floors and vandal resistant wall systems. Heavy Duty System icon represents heavy-duty load carrying capability for floors and vandal resistant wall systems. ADA Compliant icon represents systems that comply with the Americans with Disabilities Act guideline.

GID
Total
Movement
Joint Opening "A"
Cover
Block Out
Thermal Min.
Nominal
Thermal Max.
"B"
"C"
GID-200 3.0 76 1.0 25 2.0 51 3.0 76 7.0 178 4.125 105
GID-300 4.5 114 1.5 38 3.0 76 4.5 114 8.50 216 5.125 130
GID-400 6.0 152 2.0 51 4.0 102 6.0 152 10.0 254 6.125 156
GID-500 7.5 191 2.5 64 5.0 127 7.5 191 11.5 292 7.125 181
GID-600 9.0 229 3.0 76 6.0 152 9.0 229 13.0 330 8.125 206
GID-700 10.5 267 3.5 89 7.0 178 10.5 267 14.5 368 9.125 232
GID-800 12.0 305 4.0 102 8.0 203 12.0 305 16.0 406 10.125 257
GID-900 13.5 343 4.5 114 9.0 229 13.5 343 17.5 445 11.125 283
GID-1000 15.0 381 5.0 127 10.0 254 15.0 381 19.0 483 12.125 308

Joint Opening "A" can close to 0" during a seismic event.
Dimensions shown in inches (bold) and millimeters.