HEAVY DUTY FLOOR COVER SYSTEM

Fire Rated System icon represents approvals and listings with accredited laboratories. Waterproof System icon represents expansion joints that provide a watertight exterior seal. Seismic Design icon represents systems that accommodate multi-directional seismic movement. Heavy Duty System icon represents heavy-duty load carrying capability for floors and vandal resistant wall systems. ADA Compliant icon represents systems that comply with the Americans with Disabilities Act guideline. No-Bump System icon represents expansion joints that provide flush, no-bump floor-to-floor transitions.

SSP Total Movement Joint Opening "A" Slide Plate Thickness Slide Plate "B" Blockout "C"
Seismic Min. Thermal Min. Nominal Thermal Max.
SSP-400 5.0 127 1.00 25 2.0 51 4.0 102 6.0 152 0.375 10 8.0 203 4.5 114
SSP-600 8.0 203 1.00 25 3.0 76 6.0 152 9.0 229 0.375 10 11.0 279 5.5 140
SSP-800 11.0 279 1.00 25 4.0 102 8.0 203 12.0 305 0.375 10 14.0 356 6.5 165
SSP-1000 14.0 356 1.00 25 5.0 127 10.0 254 15.0 381 0.375 10 17.0 432 7.5 191
SSP-1200 14.0 356 1.00 25 5.0 127 12.0 305 15.0 381 0.375 10 17.0 432 7.5 191