MODELS |
FEATURES |
NOMINAL
OPENING |
MOVEMENT
RANGE |
MOVEMENT
TYPE |
CODES/LOADING
TRAFFIC TYPE |
APPLICATIONS |
|
- Interlocking dual slide plate assembly provides flush floor-to-floor transition.
- Six-way multi-directional seismic movement
- Pedestrian friendly and ADA compliant.
- Provides flush no-bump transition
- Accommodates heavy loads with solid or pneumatic tires.
- Optional fabric reinforced rubber gutter for Fire Barriers - 2 to 4 hour fire protection ratings
|
2" - 6"
52 - 152 |
.75"-2.25"
19 - 57 |
|
ADA
Pedestrian
Seismic |
- No Bump
- Hospital, Healthcare, Nursing Home
- Floor-To-Floor and Floor-to-wall
- Heavy Mobile Equipment
|
|
- Flush sightline minimizes appearance.
- Seals available in eight standard colors.
- Matching sightlines for floor and walls.
- Wide range of frame styles.
|
1"-12"
25 - 305
|
.65"-26"
17 - 660
|
|
ADA
Pedestrian Vertical |
- No Bump
- New-to-New or New-to-Existing
- Floor-to-Floor and Floor-to-Wall
- Color Coordination to Adjacent Surfaces
- Carpet or Tile Insets for Floors
- Mud-In Frames for Walls
|
|
- Minimal sightline (exposed surface).
- Accommodates vertical displacement.
- Floor and wall models.
- Accepts a variety of floor finishes.
- Optional brass or stainless trim strips.
|
2"-6"
51 - 152
|
1"-9"
25 - 229
|
|
ADA
Heavy
Pedestrian |
- New-to-New and New-to-Existing
- Floor-to-Floor and Corner Conditions
- Heavy Pedestrian Areas
- Carpeted Surfaces
|
|
- Accommodates vertical displacement.
- Durable aluminum frames and covers.
- Exposed or recessed cover styles.
- Accepts a variety of floor finishes.
- New-to-existing and corner styles available.
|
1"-4"
25 - 102
|
0"-6"
0 - 152
|
|
ADA
Pedestrian |
- New-to-New and New-to-Existing
- Floor-to-Floor and Corner Conditions
- Tile or Carpet Floor Finishes
- High Traffic Areas
- Airports
- Shopping Malls
- Educational Facilities
|
|
- Rugged, extra heavy duty design.
- Surface mount and block-out installation.
- Thermal and seismic movement designs.
- Low, minimal bump designs.
|
2"-24"
51 - 600
|
1"-27"
25 - 686
|
|
ADA
Pedestrian
Forklift
Limited
Vehicular |
- Transportation Hubs
- Convention Centers
- Postal Facilities
- Money Carts
- Heavy Mobile Equipment
- Pedestrian Bridges
|
|
- Flush, no-bump designs.
- Variable recesses.
- Accommodates various floor finishes.
- Thermal and seismic movement designs.
|
1"-24"
25 - 600
|
0"-24"
0 - 600
|
|
ADA
Pedestrian |
- Hospital, Healthcare, Nursing Home
- Calibrated Equipment Environments
- Convention Centers
- Transportation Hubs
- Money Carts
- Pedestrian Bridges
|
|
- Accommodates full seismic movement.
- Efficient centering bar cover system.
- Wide range of size/style combinations.
- Flush or surface cover styles.
|
1"-24"
25 - 600
|
0"-27"
0 - 686
|
|
ADA
Pedestrian
Seismic |
- Seismic Zones
- New-to-New and New-to-Existing
- Floor-to-Floor and Corner Conditions
- Commercial and Institutional Structures
|
|
- Load rated heavy-duty aluminum slide plates.
- HSC hinge design accommodates vertical offsets
in concrete decks.
- Optional fabric reinforced rubber waterproofing
gutters.
- ADA compliant non-slip raised pattern designs.
|
1"-24" 25
- 600 |
0"-27" 0
- 686 |
|
Pedestrian
ADA |
- Surface Mount Applications
- Gym Floors
- Carpet/Tile
- Concrete/Wood Floors
|
|
- ASTM Test Standards E-119, E-1399 and E-1966.
- Additional Standards: UL 263, UL 2079, UBC 43-1,
UBC 7-1, ANSI A2.1 and NFPA 251.
- Available in 2, 3, 4 and 5 hour ratings and cycle
tested for class I, II and III movement including
lateral shear.
- Listed with UL, Intertek (Omega Point Laboratories), and California
State Fire Marshall.
|
1"-32"
25 - 813
|
0"-48"
0 - 1219
|
|
Fire Ratings:
1 hour
2 hour
3 hour
4 hour
5 hour |
- Horizontal Concrete Joint Openings
- Vertical Concrete & MasonryJoint Openings
- Vertical Gypboard Joint Openings
|
|
- Fire Rated Designs.
- Accomodates Base -Isolation Movement Requirements.
- Accommodates Various Floor Finishes.
- Wide Nominal Openings and Movement Ranges.
- Tested and listed to current code requirements.
|
12+"
305+
|
100% |
|
ADA Fire
Ratings:
2 hour
3 hour |
- Corridor Wraps
- Exterior Moat
- Hospitals
- Heavy Loads
- Co-Planar Shear Applications
- Accommodates Rotation Movement in Z Axis Base Isolated
Structures
|
|
|
MODELS |
FEATURES |
NOMINAL
OPENING |
MOVEMENT
RANGE |
MOVEMENT
TYPE |
CODES/LOADING
TRAFFIC TYPE |
APPLICATIONS |
|
- Flush sightline minimizes appearance.
- Seals available in eight standard colors.
- Matching sightlines for floor and walls.
- Wide range of frame styles.
|
1"-12"
25 - 305 |
.65"-26"
17 - 660 |
|
ADA
Pedestrian Vertical |
- No Bump
- New-to-New or New-to-Existing
- Floor-to-Floor and Floor-to-Wall
- Color Coordination to Adjacent Surfaces
- Carpet or Tile Insets for Floors
- Mud-In Frames for Walls
|
|
- Seals available in decorator colors.
- Wall and ceiling frame styles.
- Replaceable elastomeric seals.
- Mud-in frames for gypsum walls.
|
1"-5"
25 - 127 |
.5"-7.5"
13 - 191 |
|
Vertical |
- Gypsum Walls
- Gypsum or Drop Ceiling Applications
- Interior Vertical Openings
- Color Coordination to Adjacent Surfaces
- Cost Effective Designs
- Flat-to-Flat and Corner Conditions
|
|
- Sturdy and durable aluminum covers.
- Standard anodized or Kynar, 500®/Hylar, 5000® finishes.
- Accepts most wall finishes.
- Durable and vandal resistant.
|
1"-8" 25 - 203 |
0"-12" 0 - 305 |
|
Vertical |
- Gypsum, Block or Other Substrates
- Wall or Ceiling Applications
- Flat-to-Flat and Corner Conditions
- Interior Vertical Applications
- Color Coordination to Adjacent Surfaces
|
|
- Minimal sightline (exposed surface).
- Accommodates vertical displacement.
- Floor and wall models.
- Accepts a variety of floor finishes.
- Optional brass or stainless trim strips.
|
2"-6"
51 - 152 |
1"-9"
25 - 229 |
|
ADA
Heavy
Pedestrian |
- New-to-New and New-to-Existing
- Floor-to-Floor and Corner Conditions
- Heavy Pedestrian Areas
- Carpeted Surfaces
|
|
- Seismic centering device. o Solid aluminum construction. o Surface and flush mount options. o Durable and vandal resistant.
|
1"-24" 25 - 600 |
20"-48" 508 - 1200 |
|
Vertical Horizontal Ceiling Soffit |
- Interior Walls and Ceilings
- Exterior Walls and Soffits
- Watertight Moisture Barrier
- Kynar, Color Options
|
|
- Seismic seal snap locked into aluminum frames.
- No visible aluminum or hardware.
- Visual seals available in colors.
- Resistant to UV, o-zone, acid rain, most chemicals and extreme temps.
|
2"-24" 52 - 610 |
1"-36" 25 - 914 |
|
Vertical Soffit Ceilings |
- Vertical Seismic Joints
- Vertical Precast
- Available Secondary Water Seal
- Color Matching of Wall Finishes
|
|
- Preformed silicone strip bonded to a rectangular polyurethane backer creates a binary sealing system.
- System conforms to irregular openings and is soundproof, dust-proof, water and air tight.
- Engineered 1/2" thick preformed silicone strip virtually eliminates possibility of punctures.
- Resistant to UV, ozone, and extreme temperatures.
|
1"-5" 25 - 127 |
.5"-7.5" 13 - 191 |
|
Vertical
|
- Color Matching of Wall Finishes
- Vertical Brick & Block Walls
- Vertical Precast & Perimeter Walls
- Abutments
- Stair Tower & Slab-to-Wall Conditions
- Vertical Joints with No Blockouts
- Irregular Expansion Joint Openings
|
|
- ASTM Test Standards E-119, E-1399 and E-1966.
- Additional Standards: UL 263, UL 2079, UBC 43-1, UBC 7-1, ANSI A2.1 and NFPA 251.
- Available in 2, 3, 4 and 5 hour ratings and cycle tested for class I, II and III movement including lateral shear.
- Listed with UL, Intertek (Omega Point Laboratories), and California State Fire Marshall.
|
1"-32"
25 - 813 |
0"-48"
0 - 1219 |
|
Fire Ratings:
1 hour
2 hour
3 hour
4 hour
5 hour |
- Horizontal Concrete Joint Openings
- Vertical Concrete & MasonryJoint Openings
- Vertical Gypboard Joint Openings
|
|
- Fire Rated Designs.
- Accomodates Base -Isolation Movement Requirements.
- Accommodates Various Floor Finishes.
- Wide Nominal Openings and Movement Ranges.
- Tested and listed to current code requirements.
|
12+"
305+ |
100% |
|
ADA Fire Ratings:
2 hour
3 hour |
- Corridor Wraps
- Exterior Moat
- Hospitals
- Heavy Loads
- Co-Planar Shear Applications
- Accommodates Rotation Movement in Z Axis Base Isolated Structures
|
|
|
MODELS |
FEATURES |
NOMINAL
OPENING |
MOVEMENT
RANGE |
MOVEMENT
TYPE |
CODES/LOADING
TRAFFIC TYPE |
APPLICATIONS |
|
- Seismic seal snap locked into aluminum frames.
- No visible aluminum or hardware.
- Visual seals available in colors.
- Resistant to UV, o-zone, acid rain, most chemicals and extreme temps.
|
2"-24" 52 - 610 |
1"-36" 25 - 914 |
|
Vertical Soffit Ceilings |
- Vertical Seismic Joints
- Vertical Precast
- Available Secondary Water Seal
- Color Matching of Wall Finishes
|
|
- Preformed silicone strip bonded to a rectangular polyurethane backer creates a binary sealing system.
- System conforms to irregular openings and is soundproof, dust-proof, water and air tight.
- Engineered 1/2" thick preformed silicone strip virtually eliminates possibility of punctures.
- Resistant to UV, ozone, and extreme temperatures.
|
1"-5" 25 - 127 |
.5"-7.5" 13 - 191 |
|
Vertical
|
- Color Matching of Wall Finishes
- Vertical Brick & Block Walls
- Vertical Precast & Perimeter Walls
- Abutments
- Stair Tower & Slab-to-Wall Conditions
- Vertical Joints with No Blockouts
- Irregular Expansion Joint Openings
|
|
- Seismic centering devices.
- Resistant to snow loads.
- Flat or slopped roofs.
- Optional Kynar/Hylar finishes.
- Water-resistant design.
- Secondary moisture barrier.
- Factory transitions available.
|
1"-24"
25 - 610 |
0"-36"
0 - 914 |
|
Non-traffic
Horizontal
Vertical |
- Color to match / compliment adjacent materials
- Water resistant applications
- Roof and Exterior Walls and Soffits
|
|
- Resistant to UV, ozone, acid rain, most chemicals and extreme temperatures.
- Flat or sloped roofs.
- Factory transitions available.
- Optional secondary moisture barrier.
|
2"- 6 "
50 - 150 |
0"-12"
0 - 305 |
|
Non-traffic
Horizontal
Vertical |
- Water resistant applications
- Roof and Exterior Walls and Soffits
|
|
- ASTM Test Standards E-119, E-1399 and E-1966.
- Additional Standards: UL 263, UL 2079, UBC 43-1, UBC 7-1, ANSI A2.1 and NFPA 251.
- Available in 2, 3, 4 and 5 hour ratings and cycle tested for class I, II and III movement including lateral shear.
- Listed with UL, Intertek (Omega Point Laboratories), and California State Fire Marshall.
|
1"-32"
25 - 813 |
0"-48"
0 - 1219 |
|
Fire Ratings:
1 hour
2 hour
3 hour
4 hour
5 hour |
- Horizontal Concrete Joint Openings
- Vertical Concrete & MasonryJoint Openings
- Vertical Gypboard Joint Openings
|
|
|
MODELS |
FEATURES |
NOMINAL
OPENING |
MOVEMENT
RANGE |
MOVEMENT
TYPE |
CODES/LOADING
TRAFFIC TYPE |
APPLICATIONS |
|
- Waterproof expansion joint sealing systems.
- Elastomeric concrete that flexes with deck loads.
- Engineered to withstand heavy traffic loads and extreme weather conditions.
- Continuous Elastoprene® seals are ADA compliant.
- Available with a 5-Year warranty.
|
1"-10"
25 - 254 |
.75"-12.5"
19 - 318 |
|
ADA
Vehicular
Pedestrian
Snow Plows Delivery
Vertical |
- Watertight
- Split Slab Waterproof Conditions
- Color Options Available
- Parking Decks
- Plazas & Concourses
- Snow Plow Areas
- Fork Truck Traffic
|
|
|