by Design Guide
by Site Map



Browse EMC Drawing Files
Working in BIM?


Related System:
CIS


EMC Spec Data Sheet
(.pdf)
Elastobond Activator Spec Data (.pdf)
Multi-Product Spec (.doc)
Maintenance Guidelines (.pdf)


103 AAR in Concrete
107 Expansion Joint Rubber Hardness, Mass & Density
110 Concrete Surface Prep.
111 Ferrous Metal Surface Prep.
129 Tech Bulletin - Snow Removal Guideline


EJP Project Reference List




ElastoLok® MEMBRANE SYSTEM (EMS)


EMS Main Page | Switch to EMS | Switch to EMS-C | Switch to EMC

Fire Rated System icon represents approvals and listings with accredited laboratories. Waterproof System icon represents availablility of a 5-year watertight warranty through our Certified Contractor Network. Heavy Duty System icon represents heavy-duty load carrying capability for floors and vandal resistant wall systems. ADA Compliant icon represents systems that comply with the Americans with Disabilities Act guideline.

 

EMC-C Total Movement Joint Opening "A" Installation Range "A" Depth "B"
Thermal Min. Thermal Max. Max. Extension Minimum Maximum Clearance
EMC-C-250 2.50 64 0.75 19 2.50 64 3.25 83 1.25 32 2.25 57 2.625 67
EMC-C-350 3.25 83 1.00 25 3.50 89 4.25 108 1.50 38 3.25 83 2.625 67
EMC-C-450 4.00 102 1.50 38 4.50 114 5.50 140 2.25 57 4.25 108 2.625 67
EMC-C-550 5.00 127 1.50 38 5.50 140 6.50 165 3.00 76 5.25 133 2.625 67

Dimensions shown in inches (bold) and millimeters (non-bold).
Color Options for Seal - Black or Special Order Gray.

Width "A" is the seal's relaxed dimension.
Depth "B" is a fully compressed clearance dimension.

Safety Maximum - Safety margin movement capacity accomodates concrete shrinkage, vertical displacement, and unexpected movement.

Contact MM Systems for below grade applications.