Fire Rated System icon represents approvals and listings with accredited laboratories. Waterproof System icon represents expansion joints that provide a watertight exterior seal. Seismic Design icon represents systems that accommodate multi-directional seismic movement. Heavy Duty System icon represents heavy-duty load carrying capability for floors and vandal resistant wall systems. ADA Compliant icon represents systems that comply with the Americans with Disabilities Act guideline. No-Bump System icon represents expansion joints that provide flush, no-bump floor-to-floor transitions.

SSP-C Total Movement Joint Opening "A" Slide Plate Thickness Slide Plate "B" Blockout "C" Blockout "D"
Seismic Min. Thermal Min. Nominal Seismic Max.
SSP-C-400 3.25 83 1.75 44 3.0 76 4.0 102 5.0 127 0.375 10 6.0 152 4.5 114 1.875 48
SSP-C-600 5.75 146 1.75 44 4.5 114 6.0 152 7.5 191 0.375 10 8.5 216 5.5 140 1.875 48
SSP-C-800 8.25 210 1.75 44 6.0 152 8.0 203 10.0 254 0.375 10 11.0 279 6.5 165 1.875 48
SSP-C-1000 10.75 273 1.75 44 7.5 191 10.0 254 12.5 318 0.375 10 13.5 343 7.5 191 1.875 48
SSP-C-1200 13.75 337 1.75 44 9.0 229 12.0 305 15.0 381 0.5 13 16.0 406 8.5 216 2.0 51