by Design Guide
by Site Map



Browse EIH Drawing Files
Working in BIM?


EIH Spec-Data Sheet (.pdf)
Multi-Product Spec (.doc)
High Strength Epoxy Spec Data (.pdf)

Maintenance Guidelines (.pdf)


110 Concrete Surface Prep.
111 Ferrous Metal Surface Prep.

121 Sound Attenuation
122 R-Value


EJP Project Reference List



EXPANDING HEALER-SEALER FOAM SEAL (EIH Series)


EIH Main Page

Fire Rated System icon represents approvals and listings with accredited laboratories. Heavy Duty System icon represents heavy-duty load carrying capability for floors and vandal resistant wall systems. Seismic Design icon represents systems that accommodate multi-directional seismic movement. Narrow Sightline icon represents expansion joints that provide a narrow and aesthetically pleasing sightline.

EIH
Total
Movement
Movement Range "A"
Expansion Joint Size
Minimum
Maximum
Nominal
Seal Depth
EIH-050 0.50 13 0.250 6 0.750 19 0.50 13 1.5 38
EIH-063 0.63 16 0.312 8 0.938 24 0.63 16 1.5 38
EIH-075 0.75 19 0.375 10 1.125 29 0.75 19 1.5 38
EIH-100 1.00 25 0.500 13 1.500 38 1.00 25 2.0 51
EIH-125 1.25 32 0.625 16 1.875 48 1.25 32 2.0 51
EIH-150 1.50 38 0.750 19 2.250 57 1.50 38 2.0 51
EIH-175 1.75 44 0.875 22 2.625 67 1.75 44 2.0 51
EIH-200 2.00 51 1.000 25 3.000 76 2.00 51 3.0 76
EIH-225 2.25 57 1.125 28 3.375 86 2.25 57 3.0 76
EIH-250 2.50 64 1.250 32 3.750 95 2.50 64 3.0 76
EIH-275 2.75 70 1.375 35 4.150 105 2.75 70 3.0 76
EIH-300 3.00 76 1.500 38 4.500 114 3.00 76 3.0 76
EIH-325 3.25 83 1.562 41 4.812 122 3.25 83 3.0 76
EIH-350 3.50 89 1.750 44 5.250 133 3.50 89 3.0 76
EIH-375 3.75 96 1.875 48 5.625 143 3.75 96 4.0 102
EIH-400 4.00 102 2.000 51 6.000 152 4.00 102 4.0 102
EIH-500 5.00 127 2.500 64 7.500 191 5.00 127 4.0 102
EIH-600 6.00 152 3.000 76 9.000 229 6.00 152 4.0 102
EIH-700 7.00 178 3.500 89 10.50 267 7.00 178 5.0 127
EIH-800 8.00 203 4.000 102 12.00 305 8.00 203 5.0 127

Dimensions shown in inches (bold) and millimeters.
Contact MM Systems for additional sizes.