Fire Rated System icon represents approvals and listings with accredited laboratories. Waterproof System icon represents expansion joints that provide a watertight exterior seal. Seismic Design icon represents systems that accommodate multi-directional seismic movement. Heavy Duty System icon represents heavy-duty load carrying capability for floors and vandal resistant wall systems. ADA Compliant icon represents systems that comply with the Americans with Disabilities Act guideline.

SHS Total Movement Joint Opening "A" Slide Plate "B" Slide Plate Thickness "C"
Seismic Min. Nominal Seismic Max.
SHS-300 3.00 76 1.50 38 3.00 76 4.50 114 8.00 203 0.375 10
SHS-400 4.00 102 2.00 51 4.00 102 6.00 152 8.00 203 0.375 10
SHS-500 5.00 127 2.50 64 5.00 127 7.50 191 11.00 279 0.375 10
SHS-600 6.00 152 3.00 76 6.00 152 9.00 229 11.00 279 0.375 10
SHS-700 7.00 178 3.50 89 7.00 178 10.50 267 14.00 356 0.375 10
SHS-800 8.00 203 4.00 102 8.00 203 12.00 305 14.00 356 0.375 10

Dimensions are shown in inches (bold) and millimeters. Thermal Maximum determined on a project specific basis.
Slide plate thickness is based on the maximum thermal opening for regular vehicle loading.